hvl_ccb.dev.fug
Submodules
- hvl_ccb.dev.fug.fug
FuG
FuGConfig
FuGDigitalVal
FuGError
FuGErrorcodes
FuGErrorcodes.E0
FuGErrorcodes.E1
FuGErrorcodes.E10
FuGErrorcodes.E100
FuGErrorcodes.E106
FuGErrorcodes.E11
FuGErrorcodes.E115
FuGErrorcodes.E12
FuGErrorcodes.E125
FuGErrorcodes.E13
FuGErrorcodes.E135
FuGErrorcodes.E14
FuGErrorcodes.E145
FuGErrorcodes.E15
FuGErrorcodes.E155
FuGErrorcodes.E16
FuGErrorcodes.E165
FuGErrorcodes.E2
FuGErrorcodes.E206
FuGErrorcodes.E306
FuGErrorcodes.E4
FuGErrorcodes.E5
FuGErrorcodes.E504
FuGErrorcodes.E505
FuGErrorcodes.E6
FuGErrorcodes.E666
FuGErrorcodes.E7
FuGErrorcodes.E8
FuGErrorcodes.E9
FuGErrorcodes.raise_()
FuGMonitorModes
FuGPolarities
FuGProbusIV
FuGProbusIVCommands
FuGProbusIVCommands.ADMODE
FuGProbusIVCommands.CURRENT
FuGProbusIVCommands.EXECUTE
FuGProbusIVCommands.EXECUTEONX
FuGProbusIVCommands.ID
FuGProbusIVCommands.OUTPUT
FuGProbusIVCommands.POLARITY
FuGProbusIVCommands.QUERY
FuGProbusIVCommands.READBACKCHANNEL
FuGProbusIVCommands.RESET
FuGProbusIVCommands.TERMINATOR
FuGProbusIVCommands.VOLTAGE
FuGProbusIVCommands.XOUTPUTS
FuGProbusV
FuGProbusVConfigRegisters
FuGProbusVDIRegisters
FuGProbusVDORegisters
FuGProbusVMonitorRegisters
FuGProbusVRegisterGroups
FuGProbusVRegisterGroups.CONFIG
FuGProbusVRegisterGroups.INPUT
FuGProbusVRegisterGroups.MONITOR_I
FuGProbusVRegisterGroups.MONITOR_V
FuGProbusVRegisterGroups.OUTPUTONCMD
FuGProbusVRegisterGroups.OUTPUTX0
FuGProbusVRegisterGroups.OUTPUTX1
FuGProbusVRegisterGroups.OUTPUTX2
FuGProbusVRegisterGroups.OUTPUTXCMD
FuGProbusVRegisterGroups.SETCURRENT
FuGProbusVRegisterGroups.SETVOLTAGE
FuGProbusVSetRegisters
FuGRampModes
FuGReadbackChannels
FuGSerialCommunication
FuGSerialCommunicationConfig
FuGSerialCommunicationConfig.baudrate
FuGSerialCommunicationConfig.bytesize
FuGSerialCommunicationConfig.default_n_attempts_read_text_nonempty
FuGSerialCommunicationConfig.force_value()
FuGSerialCommunicationConfig.keys()
FuGSerialCommunicationConfig.optional_defaults()
FuGSerialCommunicationConfig.parity
FuGSerialCommunicationConfig.required_keys()
FuGSerialCommunicationConfig.stopbits
FuGSerialCommunicationConfig.terminator
FuGSerialCommunicationConfig.timeout
FuGSerialCommunicationConfig.wait_sec_read_text_nonempty
FuGTerminators
Module contents
Device classes for “Probus V - ADDAT30” Interfaces which are used to control power supplies from FuG Elektronik GmbH
This interface is used for many FuG power units. Manufacturer homepage: https://www.fug-elektronik.de
The Professional Series of Power Supplies from FuG is a series of low, medium and high voltage direct current power supplies as well as capacitor chargers. The class FuG is tested with a HCK 800-20 000 in Standard Mode. The addressable mode is not implemented. Check the code carefully before using it with other devices. Manufacturer homepage: https://www.fug-elektronik.de/netzgeraete/professional-series/
The documentation of the interface from the manufacturer can be found here: https://www.fug-elektronik.de/wp-content/uploads/download/de/SOFTWARE/Probus_V.zip
The provided classes support the basic and some advanced commands. The commands for calibrating the power supplies are not implemented, as they are only for very special porpoises and should not used by “normal” customers.