Errors and their codes of FuG
"""
import logging
from hvl_ccb.dev.base import DeviceError
from hvl_ccb.utils.enum import NameEnum
logger = logging.getLogger(__name__)
[docs]
class FuGError(DeviceError):
"""
Error with the FuG voltage source.
"""
def __init__(self, *args, **kwargs) -> None:
self.errorcode: str = kwargs.pop("errorcode", "")
"""
Errorcode from the Probus, see documentation of Probus V chapter 5.
Errors with three-digit errorcodes are thrown by this python module.
"""
super().__init__(*args, **kwargs)
[docs]
class FuGErrorcodes(NameEnum, init="description possible_reason"): # type: ignore[call-arg]
"""
The power supply can return an errorcode. These errorcodes are handled by this
class. The original errorcodes from the source are with one or two digits,
see documentation of Probus V chapter 5.
All three-digit errorcodes are from this python module.
"""
E0 = "no error", "standard response on each command"
E1 = (
"no data available",
(
"Customer tried to read from GPIB but there were no data prepared. "
"(IBIG50 sent command ~T2 to ADDA)"
),
)
E2 = "unknown register type", "No valid register type after '>'"
E4 = (
"invalid argument",
"The argument of the command was rejected .i.e. malformed number",
)
E5 = "argument out of range", "i.e. setvalue higher than type value"
E6 = (
"register is read only",
"Some registers can only be read but not written to. (i.e. monitor registers)",
)
E7 = "Receive Overflow", "Command string was longer than 50 characters."
E8 = (
"EEPROM is write protected",
(
"Write attempt to calibration data while the write protection switch was"
" set to write protected."
),
)
E9 = (
"address error",
(
"A non addressed command was sent to ADDA while it was in addressable mode "
"(and vice versa)."
),
)
E10 = "unknown SCPI command", "This SCPI command is not implemented"
E11 = (
"not allowed Trigger-on-Talk",
(
"Not allowed attempt to Trigger-on-Talk (~T1) while ADDA was in addressable"
" mode."
),
)
E12 = "invalid argument in ~Tn command", "Only ~T1 and ~T2 is implemented."
E13 = (
"invalid N-value",
(
"Register > K8 contained an invalid value. Error code is output on an"
" attempt to query data with ? or ~T1"
),
)
E14 = "register is write only", "Some registers can only be writte to (i.e.> H0)"
E15 = "string too long", "i.e.serial number string too long during calibration"
E16 = (
"wrong checksum",
(
"checksum over command string was not correct, refer also to 4.4 of the "
"Probus V documentation"
),
)
E100 = (
"Command is not implemented",
"You tried to execute a command, which is not implemented or does not exist",
)
E106 = (
"The rampstate is a read-only register",
(
"You tried to write data to the register, which can only give "
"you the status of the ramping."
),
)
E206 = (
"This status register is read-only",
(
"You tried to write data to this "
"register, which can only give you "
"the actual status of the "
"corresponding digital output."
),
)
E306 = (
"The monitor register is read-only",
"You tried to write data to a monitor, which can only give you measured data.",
)
E115 = (
"The given index to select a digital value is out of range",
"Only integer values between 0 and 1 are allowed.",
)
E125 = (
"The given index to select a ramp mode is out of range",
"Only integer values between 0 and 4 are allowed.",
)
E135 = (
"The given index to select the readback channel is out of range",
"Only integer values between 0 and 6 are allowed.",
)
E145 = (
"The given value for the AD-conversion is unknown",
'Valid values for the ad-conversion are integer values from "0" to "7".',
)
E155 = (
"The given value to select a polarity is out range.",
"The value should be 0 or 1.",
)
E165 = "The given index to select the terminator string is out of range", ""
E504 = "Empty string as response", "The connection is broken."
E505 = (
"The returned register is not the requested.",
"Maybe the connection is overburden.",
)
E666 = (
(
"You cannot overwrite the most recent error in the interface of the power"
" supply. But, well: You created an error anyway..."
),
"",
)
[docs]
def raise_(self) -> None:
"""
Evaluate the error code and raise a `FuGError` if the error code is not `E0`
"""
if self is FuGErrorcodes.E0:
logger.debug('Communication with FuG successful, errorcode "E0" received.')
return
logger.debug(f"A FuGError with the errorcode {self.name} was detected.")
msg = f"{self.description}. Possible reason: {self.possible_reason}"
logger.exception(msg)
raise FuGError(msg, errorcode=self.name)